Since 2009 the reference point for Wi-Fi in Italy
Soppressor for PoE lines
It is designed for surge protection of devices connected to the ethernet 10 / 100Mbps using the 2 UTP / FTP cable pairs for powering PoE devices.
It has two separate protection circuits, namely one for the data transmission lines (1-2, 3-6) and one for power (4-5, 7-8).
The two circuits are protected by elements that downloading any overloaded to the ground.
In order to increase the maximum load of the PoE circuit, the cable 4 is connected in parallel with the 5 and 7 cable with the cable 8.
N.B. the protector works by connecting the yellow / green wire to the ground or to a protective conductor.
Specifications:
Data | Power supply | |
Nominal voltage [V] | 5 | 5 to 50 |
Max voltage [V] | 6 | 56 |
Threshold voltage (cable-cable) [V] | <40 | <125 |
Threshold voltage (cable-ground) [V] | <600 | <1000 |
Nominal discharge current (cable-cable) | 100 A - 8/20 μs | 80 A - 8/20 μs |
Nominal discharge current (cable-ground) | 100 A - 8/20 μs | 1000 A - 8/20 μs |
Max discharge current (cable-cable) | 135 A - 8/20 μs | - |
Max discharge current (cable-ground) | 135 A - 8/20 μs | 2.5 kA - 8/20 μs |
Protect pairs | 1-2, 3-6 | 4-5, 7-8 |
Connectors | RJ-45 | |
Dimensions [mm] | 66x60x30 | |
Weigth [kg] | 0.06 |